Przedstawione poniżej akcesoria mogą być stosowane w różnego typu aplikacjach. Aby uzyskać więcej informacji technicznych o produktach, kliknij link znajdujący się pod zdjęciem każdego z nich.
BAJ
The BAJ battery pack has been specially developed for use with the JUMBO system. The battery pack is easy to exchange through an integrated snap system.
Data sheet
|
CHJ2
The CHJ2 charger has been specially designed for use as a wall-charger for the JUMBO system.
Data sheet
|
COBO20
The COBO20 is specially developed for use together with the JUMBO battery pack and CU20.
Data sheet
|
CH01

Do ładowania akumulatorów do skrzynek CB08-XA oraz wszystkich modeli JUMBO™, podłączonych bezpośrednio do skrzynki kontrolnej lub za pośrednictwem pilota HB40A. Z wymiennymi wtyczkami, optymalizującymi logistykę.
Specyfikacja
|
CH8

For charging of the batteries in the control box CB8-XA, directly connected to the control box or via the handset HB40A.
Data sheet
|
Mains cut-off
The mains cut-off disconnects the mains voltage so that there is no mains voltage in the CB and mains cable when not in operation.
Data sheet
|
|
DJBH
The DIN Junction Box is designed for the use with 2 x TWINDRIVE TD1 220, 250 or TD1 280 simultaneously with 1 or 2 controls.
Data sheet
|
DJB
The DIN Junction Box is designed for use where there is a need for more than 1 or 2 controls to be connected to a control box.
Data sheet
|
MJB

The MJB Modular Junction Box is designed for use together with the CB20 and other OPENBUS™ control boxes. The MJB makes it possible to connect handsets, attendant controls and accessories with the CB20.
Datasheet
|
SLS
Safety Limit Switch SLS. The SLS cuts off the current from the motor in either out- or inwards direction. Can also be used as signal switch. The SLS is available in protection class up to IP66 washable.
For all LINAK® actuators.
Data sheet
|
IRO
IRO is a part of the accessory portfolio - available for the CB OPENBUSTM familiy. The Receiver is fitted to the bed so that the bed moveement can be controlled with signals received from a remote control.
Data sheet
|
LS/LSD
Limit Switches LS/LSD. For industry actuators.
Data sheet
|
CS16
Electronic Limit Switches.
For industry actuators.
Data sheet
|
Extension cables
LINAK has a range of extension cables and T-cables for handsets, desk panels and foot switches. LINAK also offers a range of extension cables for actuators.
No data sheet available.
|
MBJ
Mounting brackets for the JUMBO system.
Data sheet
|
BA18
The BA18 has been developed for use with the control boxes: CB14, CB12 and CB9. BA18 has a capacity of 1.2 Ah at 24 V DC.
Data sheet
|
TR6
The TR6 is a seperate external power supply box, which can be wall mounted or placed on the floor.
- Input 230V - output 24V AC.
Data sheet
|
|
Potentiometer

The potentiometer is used where the absolute position of the actuator is needed.
No data sheet available.
|
Optical encoder
The optical encoder is used for positioning and servo control of an actuator.
No data sheet available.
|
Massage Motor
Massage Motor. Massage is now an option with the TD1 280 TWINDRIVE™ solution
Data sheet
|
LED Lightbox

The LED LIGHTBOX is a new TD3 accessory which brings light to your bed application. Based on plug and play principles, just connect the LED LIGHTBOX to the TD3 and you can switch the light on and off via the handset.
Data sheet
|
USB Connector

The USB CONNECTOR is a new TD3 acessory making it possible to connect a variety of standard articles equipped with a USB plug to your TWINDRIVE™ system. Based on plug and play principles, just connect the USB CONNECTOR to the TD3 and you have extended combination possibilities of adding a USB based unit.
Data sheet
|
DC Connector
The DC CONNECTOR is a new TD3 accessory making it possible to connect a variety of standard articles equipped with a DC plug to your TWINDRIVE™ system. Based on plug and play principles just connect the DC CONNECTOR to the TD3 and you have extended combination possibilities of adding a DC based unit.
Data sheet
|